HDG Steel Rapid Deployment Site Tower With Fabricated Foundation
Rapid deployment site tower with fabricated foundation

| No. | Description | Detailed Specification and Major design Parameters |
| 1 | Design Code | ANSI/TIA222G,H or European Standard and others |
| 2 | Design Loading | 1. Antenna load area as per specified by Clients worldwide. 2. Wind speed as per requested by the clients. 3. Deflection & Twist Angle, Exposure category, Topographic category as per specified by clients. |
| 4 | Structure Classification | II, III |
| 5 | Hot-dip galvanization | ISO 1461 2009, ASTM A123 |
| 6 | Steel Grade | 1. High strength low alloy structural steel: Q355 or equivalent with ASTM Gr50 or S355JR 3. Carbon Structural Steel: Q235B which is equivalent with ASTM A36 or S235JR |
| 7 | Bolts and Nuts | Mainly ISO 898 grade 6.8 and 8.8 bolts |
| 8 | Foundation | 50KPa, 100KPa, 150KPa etc soil bearing capacity |
| 9 | Tower Type |
1. 3 or 4 Leg Self supported Angular Towers 9. Street lightning pole 10. Electric transmission line towers 11. Subustation gantry 12. All kinds of other steel structures |
| 10 | Warranty | 1. Tower structures: 15 years 2. Camouflaged towers a. Barks: 10 years b. Branches and leaves: 3 years |
| 11 | Return Period | 50 Years |
| 12 | Accessories | 1. Paint kits (ICAO standards): Water Based Acrylic Anticorrosive Paint 2. Aviation Light: Double Light and Single Light & Solar Light 3. Lightning System: Lightning rod with 70mm2 G/Y copper cable down conductor or 25x3mm copper flat tape with clamps, and copper coated steel busbars or as per specified by clients. 4. Earthing System: Earthing Rod with copper clad steel strand cable and lugs etc. or as per specified by Clients. 5. Fencing: Palisade fence and wire mesh fence with razor wires and gate. 6. Fall arrest system: GB and CE certificate fall arrest system. 7. Canopy and Generator Cage: as per specified by clients |
Rapid deployment site tower
,Steel rapid deployment tower
,foundation rapid deployment tower
-
Single Or Triple Steel Antenna Tower Mounting Brackets 15years Warranty
Antenna mounted bracket No. Description Detailed Specification and Major design Parameters 1 Design Code ANSI/TIA222G,H or European Standard and others 2 Design Loading 1. Antenna load area as per specified by Clients worldwide. 2. Wind speed as per requested by the clients. 3. Deflection & Twist ... -
3 Legs Rooftop Lattice Steel Pole Concrete Base Or Anchor Bolts Type 0-300m Height
Rooftop lattice steel pole No. Description Detailed Specification and Major design Parameters 1 Design Code ANSI/TIA222G,H or European Standard and others 2 Design Loading 1. Antenna load area as per specified by Clients worldwide. 2. Wind speed as per requested by the clients. 3. Deflection & Twist ... -
0-200m Camouflaged Fake Pine Tree Cell Tower HDG Monopole For Communication
Camouflaged fake pine tree communication tower The leaves quantity and AMB arrangement and height as per client requests or we can come up with our experience. We have long-term compatible partner to offer the leaves passing the wind speed up to 290km/hr. 3 grain barks avaiable. 1 Design standard ...