Search Results For:
monopole antenna tower
(54 Items)-
3 या 4 पैरों का ग्रिड वाला मास्ट टॉवर आसान और तेज़ स्थापना
Guyed mast lattice tower No. Description Detailed Specification and Major design Parameters 1 Design Code ANSI/TIA222G,H or European Standard and others 2 Design Loading 1. Antenna load area as per specified by Clients worldwide. 2. Wind speed as per requested by the clients. 3. Deflection & Twist Angle, Exposure category, Topographic category as per specified by clients. 4 Structure Classification II, III 5 Hot-dip galvanization ISO 1461 2009, ASTM A123 6 Steel Grade 1. High -
एचडीजी या पेंटिंग हाइब्रिड जाली ट्यूबलर टॉवर 3 या 4 लेग्स 15 साल
Tubular hybrid lattice pipe tower No. Description Detailed Specification and Major design Parameters 1 Design Code ANSI/TIA222G,H or European Standard and others 2 Design Loading 1. Antenna load area as per specified by Clients worldwide. 2. Wind speed as per requested by the clients. 3. Deflection & Twist Angle, Exposure category, Topographic category as per specified by clients. 4 Structure Classification II, III 5 Hot-dip galvanization ISO 1461 2009, ASTM A123 6 Steel -
सीमलेस या वेल्डेड टेलीकॉम इलेक्ट्रिक पाईप टॉवर ट्यूबलर स्टील टॉवर HDG या पेंटिंग
Telecom electric tubular pipe tower No. Description Detailed Specification and Major design Parameters 1 Design Code ANSI/TIA222G,H or European Standard and others 2 Design Loading 1. Antenna load area as per specified by Clients worldwide. 2. Wind speed as per requested by the clients. 3. Deflection & Twist Angle, Exposure category, Topographic category as per specified by clients. 4 Structure Classification II, III 5 Hot-dip galvanization ISO 1461 2009, ASTM A123 6 Steel -
हाइब्रिड लैटिस ट्यूबलर टॉवर एएनएसआई टीआईए222जी एच और दूरसंचार इलेक्ट्रिक पाइप टॉवर के लिए यूरोपीय मानक
Hybrid Lattice Tubular Tower designed to meet ANSI TIA222G H and European standards for telecom electric pipe tower applications No. Description Detailed Specification and Major design Parameters 1 Design Code ANSI/TIA222G,H or European Standard and others 2 Design Loading 1. Antenna load area as per specified by Clients worldwide. 2. Wind speed as per requested by the clients. 3. Deflection & Twist Angle, Exposure category, Topographic category as per specified by clients. 4 -
गाइडेड ट्रांसमिशन टावर वायर एंगुलर टावर एंकर प्लेट के साथ 0-300 मीटर ऊंचाई
Guyed wire angular tower with anchor plate No. Description Detailed Specification and Major design Parameters 1 Design Code ANSI/TIA222G,H or European Standard and others 2 Design Loading 1. Antenna load area as per specified by Clients worldwide. 2. Wind speed as per requested by the clients. 3. Deflection & Twist Angle, Exposure category, Topographic category as per specified by clients. 4 Structure Classification II, III 5 Hot-dip galvanization ISO 1461 2009, ASTM A123 6 -
प्री फैब्रिकेटेड फाउंडेशन रैपिड डिप्लॉयमेंट टॉवर 3 या 4 लेग्स लैटिस
Rapid Deployment Site Tower With Pre-fabricated Foundation No. Description Detailed Specification and Major design Parameters 1 Design Code ANSI/TIA222G,H or European Standard and others 2 Design Loading 1. Antenna load area as per specified by Clients worldwide. 2. Wind speed as per requested by the clients. 3. Deflection & Twist Angle, Exposure category, Topographic category as per specified by clients. 4 Structure Classification II, III 5 Hot-dip galvanization ISO 1461 -
पूर्वनिर्मित नींव के साथ 0-300 मीटर एचडीजी रैपिड डिप्लॉयमेंट टॉवर
HDG Rapid Deployment Site Tower With Pre-fabricated Foundation No. Description Detailed Specification and Major design Parameters 1 Design Code ANSI/TIA222G,H or European Standard and others 2 Design Loading 1. Antenna load area as per specified by Clients worldwide. 2. Wind speed as per requested by the clients. 3. Deflection & Twist Angle, Exposure category, Topographic category as per specified by clients. 4 Structure Classification II, III 5 Hot-dip galvanization ISO 1461 -
दूरसंचार और विद्युत संचरण में त्वरित स्थापना और प्रदर्शन प्रदान करने वाला त्वरित तैनाती टॉवर
Rapid Deployment Tower Providing Quick Setup and Performance in Telecommunications and Electric Transmission Applications No. Description Detailed Specification and Major design Parameters 1 Design Code ANSI/TIA222G,H or European Standard and others 2 Design Loading 1. Antenna load area as per specified by Clients worldwide. 2. Wind speed as per requested by the clients. 3. Deflection & Twist Angle, Exposure category, Topographic category as per specified by clients. 4 -
इलेक्ट्रिक ट्रांसमिशन के लिए त्वरित सेटअप 3 या 4 लेग रैपिड डिप्लॉयमेंट टावर
Rapid Deployment Tower Providing Quick Setup and Performance in Telecommunications and Electric Transmission Applications No. Description Detailed Specification and Major design Parameters 1 Design Code ANSI/TIA222G,H or European Standard and others 2 Design Loading 1. Antenna load area as per specified by Clients worldwide. 2. Wind speed as per requested by the clients. 3. Deflection & Twist Angle, Exposure category, Topographic category as per specified by clients. 4