Πύργος κατάρτι πλέγματος με 3 ή 4 πόδια, εύκολη και γρήγορη εγκατάσταση
Guyed mast lattice tower No. Description Detailed Specification and Major design Parameters 1 Design Code ANSI/TIA222G,H or European Standard and others 2 Design Loading 1. Antenna load area as per specified by Clients worldwide. 2. Wind speed as per requested by the clients. 3. Deflection & Twist Angle, Exposure category, Topographic category as per specified by clients. 4 Structure Classification II, III 5 Hot-dip galvanization ISO 1461 2009, ASTM A123 6 Steel Grade 1. High -
HDG ή Ζωγραφική Υβριδικός Πύργος 3 ή 4 πόδια 15 χρόνια
Tubular hybrid lattice pipe tower No. Description Detailed Specification and Major design Parameters 1 Design Code ANSI/TIA222G,H or European Standard and others 2 Design Loading 1. Antenna load area as per specified by Clients worldwide. 2. Wind speed as per requested by the clients. 3. Deflection & Twist Angle, Exposure category, Topographic category as per specified by clients. 4 Structure Classification II, III 5 Hot-dip galvanization ISO 1461 2009, ASTM A123 6 Steel -
Χωρίς συγκόλληση ή συγκολλημένη τηλεπικοινωνιακή ηλεκτρική πύλη πύργος σωληνώδης ατσάλινος πύργος HDG ή ζωγραφική
Telecom electric tubular pipe tower No. Description Detailed Specification and Major design Parameters 1 Design Code ANSI/TIA222G,H or European Standard and others 2 Design Loading 1. Antenna load area as per specified by Clients worldwide. 2. Wind speed as per requested by the clients. 3. Deflection & Twist Angle, Exposure category, Topographic category as per specified by clients. 4 Structure Classification II, III 5 Hot-dip galvanization ISO 1461 2009, ASTM A123 6 Steel -
Υβριδικός πύργος σωληνοειδούς πλέγματος ANSI TIA222G H και ευρωπαϊκά πρότυπα για τηλεπικοινωνίες
Hybrid Lattice Tubular Tower designed to meet ANSI TIA222G H and European standards for telecom electric pipe tower applications No. Description Detailed Specification and Major design Parameters 1 Design Code ANSI/TIA222G,H or European Standard and others 2 Design Loading 1. Antenna load area as per specified by Clients worldwide. 2. Wind speed as per requested by the clients. 3. Deflection & Twist Angle, Exposure category, Topographic category as per specified by clients. 4 -
Πύργος μεταφοράς με καλώδιο με γωνιακό πύργο με άγκυρο 0-300m ύψος
Guyed wire angular tower with anchor plate No. Description Detailed Specification and Major design Parameters 1 Design Code ANSI/TIA222G,H or European Standard and others 2 Design Loading 1. Antenna load area as per specified by Clients worldwide. 2. Wind speed as per requested by the clients. 3. Deflection & Twist Angle, Exposure category, Topographic category as per specified by clients. 4 Structure Classification II, III 5 Hot-dip galvanization ISO 1461 2009, ASTM A123 6 -
Προετοιμασμένο θεμέλιο ταχείας εγκατάστασης Πύργος 3 ή 4 ποδιών Δίκτυο
Rapid Deployment Site Tower With Pre-fabricated Foundation No. Description Detailed Specification and Major design Parameters 1 Design Code ANSI/TIA222G,H or European Standard and others 2 Design Loading 1. Antenna load area as per specified by Clients worldwide. 2. Wind speed as per requested by the clients. 3. Deflection & Twist Angle, Exposure category, Topographic category as per specified by clients. 4 Structure Classification II, III 5 Hot-dip galvanization ISO 1461 -
0-300m HDG Πύργος ταχείας ανάπτυξης με προκατασκευασμένη βάση
HDG Rapid Deployment Site Tower With Pre-fabricated Foundation No. Description Detailed Specification and Major design Parameters 1 Design Code ANSI/TIA222G,H or European Standard and others 2 Design Loading 1. Antenna load area as per specified by Clients worldwide. 2. Wind speed as per requested by the clients. 3. Deflection & Twist Angle, Exposure category, Topographic category as per specified by clients. 4 Structure Classification II, III 5 Hot-dip galvanization ISO 1461 -
Πύργος Ταχείας Ανάπτυξης Παρέχοντας Γρήγορη Εγκατάσταση Και Απόδοση Στις Τηλεπικοινωνίες Και Ηλεκτρική Μεταφορά
Rapid Deployment Tower Providing Quick Setup and Performance in Telecommunications and Electric Transmission Applications No. Description Detailed Specification and Major design Parameters 1 Design Code ANSI/TIA222G,H or European Standard and others 2 Design Loading 1. Antenna load area as per specified by Clients worldwide. 2. Wind speed as per requested by the clients. 3. Deflection & Twist Angle, Exposure category, Topographic category as per specified by clients. 4 -
Γρήγορη Εγκατάσταση 3 ή 4 Πόδια Πύργοι Ταχείας Ανάπτυξης για Ηλεκτρική Μεταφορά
Rapid Deployment Tower Providing Quick Setup and Performance in Telecommunications and Electric Transmission Applications No. Description Detailed Specification and Major design Parameters 1 Design Code ANSI/TIA222G,H or European Standard and others 2 Design Loading 1. Antenna load area as per specified by Clients worldwide. 2. Wind speed as per requested by the clients. 3. Deflection & Twist Angle, Exposure category, Topographic category as per specified by clients. 4