Search Results For:
monopole steel tower
(63 Items)-
Torre tralicciata con tiranti a 3 o 4 gambe, installazione facile e veloce
Guyed mast lattice tower No. Description Detailed Specification and Major design Parameters 1 Design Code ANSI/TIA222G,H or European Standard and others 2 Design Loading 1. Antenna load area as per specified by Clients worldwide. 2. Wind speed as per requested by the clients. 3. Deflection & Twist Angle, Exposure category, Topographic category as per specified by clients. 4 Structure Classification II, III 5 Hot-dip galvanization ISO 1461 2009, ASTM A123 6 Steel Grade 1. High -
HDG o Verniciatura Griglia ibrida Torre tubolare 3 o 4 gambe 15 anni
Tubular hybrid lattice pipe tower No. Description Detailed Specification and Major design Parameters 1 Design Code ANSI/TIA222G,H or European Standard and others 2 Design Loading 1. Antenna load area as per specified by Clients worldwide. 2. Wind speed as per requested by the clients. 3. Deflection & Twist Angle, Exposure category, Topographic category as per specified by clients. 4 Structure Classification II, III 5 Hot-dip galvanization ISO 1461 2009, ASTM A123 6 Steel -
Prenotazioni per antenne a torre in acciaio singola o tripla 15 anni di garanzia
Antenna mounted bracket No. Description Detailed Specification and Major design Parameters 1 Design Code ANSI/TIA222G,H or European Standard and others 2 Design Loading 1. Antenna load area as per specified by Clients worldwide. 2. Wind speed as per requested by the clients. 3. Deflection & Twist Angle, Exposure category, Topographic category as per specified by clients. 4 Structure Classification II, III 5 Hot-dip galvanization ISO 1461 2009, ASTM A123 6 Steel Grade 1. High -
Torre autoportante secondo gli standard ANSI TIA222G H con zincatura a caldo
Self Supporting Tower designed according to ANSI TIA222G H standards with hot dip galvanization No. Description Detailed Specification and Major design Parameters 1 Design Code ANSI/TIA222G,H or European Standard and others 2 Design Loading 1. Antenna load area as per specified by Clients worldwide. 2. Wind speed as per requested by the clients. 3. Deflection & Twist Angle, Exposure category, Topographic category as per specified by clients. 4 Structure Classification II, III -
3 o 4 gambe angolari e tubolari, auto-supportabili torre a reticolo galvanizzazione a caldo resistenza alla corrosione
Self Supporting Tower featuring 3 or 4 leg angular and tubular designs with hot dip galvanization for long lasting corrosion resistance No. Description Detailed Specification and Major design Parameters 1 Design Code ANSI/TIA222G,H or European Standard and others 2 Design Loading 1. Antenna load area as per specified by Clients worldwide. 2. Wind speed as per requested by the clients. 3. Deflection & Twist Angle, Exposure category, Topographic category as per specified by -
HDG o verniciatura antenna autonoma torre velocità del vento specificata carico dell'antenna
Self Supporting Tower engineered to meet client specified wind speed antenna load No. Description Detailed Specification and Major design Parameters 1 Design Code ANSI/TIA222G,H or European Standard and others 2 Design Loading 1. Antenna load area as per specified by Clients worldwide. 2. Wind speed as per requested by the clients. 3. Deflection & Twist Angle, Exposure category, Topographic category as per specified by clients. 4 Structure Classification II, III 5 Hot-dip -
Torre autoportante a 4 gambe e 3 gambe per dispiegamento rapido e durevole
Self Supporting Tower for rapid deployment and durable No. Description Detailed Specification and Major design Parameters 1 Design Code ANSI/TIA222G,H or European Standard and others 2 Design Loading 1. Antenna load area as per specified by Clients worldwide. 2. Wind speed as per requested by the clients. 3. Deflection & Twist Angle, Exposure category, Topographic category as per specified by clients. 4 Structure Classification II, III 5 Hot-dip galvanization ISO 1461 2009, -
Torre di trasmissione con tiranti, torre angolare con piastra di ancoraggio, altezza 0-300m
Guyed wire angular tower with anchor plate No. Description Detailed Specification and Major design Parameters 1 Design Code ANSI/TIA222G,H or European Standard and others 2 Design Loading 1. Antenna load area as per specified by Clients worldwide. 2. Wind speed as per requested by the clients. 3. Deflection & Twist Angle, Exposure category, Topographic category as per specified by clients. 4 Structure Classification II, III 5 Hot-dip galvanization ISO 1461 2009, ASTM A123 6 -
Torre per antenna in acciaio reticolare da 0-300m, 3 gambe, zincata a caldo o verniciata
Rooftop lattice steel pole No. Description Detailed Specification and Major design Parameters 1 Design Code ANSI/TIA222G,H or European Standard and others 2 Design Loading 1. Antenna load area as per specified by Clients worldwide. 2. Wind speed as per requested by the clients. 3. Deflection & Twist Angle, Exposure category, Topographic category as per specified by clients. 4 Structure Classification II, III 5 Hot-dip galvanization ISO 1461 2009, ASTM A123 6 Steel Grade 1.